Process technology  
Power consumption approx. (W) 100
Production output approx. (g/Cl2/h) 16
Product concentration approx. (g/Cl2/h) 6.5
System output 100% (constantly)
Max. daily output [g/d] 384
Salt consumption approx. ([g/NaCl/h) 38
Salt carry-over into product approx. (g/NaCl/h) 21
Supply voltage (V/Hz) 230V/50Hz
Fuse right/left (A) 6.3A / 0.400
Transport weight (kg) approx. 25
Space requirements wall mounting plate (mm) (h x w x d) 1030 x 900 x 250
Space required for installation (mm) ca. 500 x 1300
Product reserve (l) 1 l (optionally extendable)
Softening plant Reverse osmosis (integrated on mounting plate)
Power module integrated on mounting plate
   
Operating conditions  
Connected load 0.3 kVA
Process water Water quality according to the European Drinking Water Ordinance
Drinking water connection 1/2“
Min./max. room temperature (°C) 10 - 32
Process water inlet temperature (°C) 10 - 27
Process water initial pressure (bar) 2.5 - 3
System pressure after pressure reducer approx. 2 bar
Hydrogen discharge min. d25 continuously rising to the outside
Ventilation of installation room Air exchange rate min. 2m³/h per m³ room volume (recommended)
Storage temperatures (°C) 5 - 40
Max. humidity (%) 90%, non-condensing
Separate technical room No
Interfaces Wi-Fi / dinoAccess
Recommended resources dinosolit salt quality (approved according to the EC Directive on Biocides)
Drain min. DN40
   
All information subject to error and technical change.