Process technology |
|
Power consumption approx. (W) |
180 |
Production output approx. (g/Cl2/h) |
26 |
Product pH level approx. (pH) |
pH7 |
Product concentration approx. (g/Cl2/h) |
depending on system output |
System output |
20 - 100% (controlled) |
Max. daily output [g/d] |
624 |
Salt consumption approx. ([g/NaCl/h) |
62 (at 100% system output) |
Salt is carried over into product |
none |
Supply voltage (V/Hz) |
230V/50Hz |
Fuse right/left (A) |
6.3A / 0.400 |
Transport weight (kg) |
approx. 33 |
Space requirements wall mounting plate (mm) |
(h x w x d) 1030 x 900 x 250 |
Space required for installation (mm) |
ca. 500 x 1300 |
Product reserve (l) |
Production in line with demand |
Softening plant |
Reverse osmosis (integrated on mounting plate) |
Power module |
integrated on mounting plate |
|
|
Operating conditions |
|
Connected load |
0.3 kVA, 1 x 230V/50Hz |
Process water |
Water quality according to the European Drinking Water Ordinance |
Drinking water connection |
1/2“ |
Min./max. room temperature (°C) |
10 - 32 |
Process water inlet temperature (°C) |
10 - 27 |
Process water initial pressure (bar) |
2.5 - 3 |
System pressure after pressure reducer |
approx. 2 bar |
Hydrogen discharge |
min. d25 continuously rising to the outside |
Ventilation of installation room |
Air exchange rate min. 2m³/h per m³ room volume (recommended) |
Storage temperatures (°C) |
5 - 40 |
Max. humidity (%) |
90%, non-condensing |
Separate technical room |
No |
Interfaces |
Wi-Fi / dinoAccess |
Recommended resources |
dinosolit salt quality (approved according to the EC Directive on Biocides) |
Drain |
min. DN40 |
|
|
All information subject to error and technical change. |