Process engineering  
Power consumption approx. (W) 180
Production capacity approx. (g/Cl2/h) 38
Product concentration approx. (g/Cl2/h) 9
Plant output 100% (constant)
max. Daily output approx. (g/d) 912
Salt consumption approx. (g/NaCl/h) 88
Salt transfer into the product approx. (g/NaCl/h) slightly
Supply voltage (V/Hz) 230V / 50Hz
Fuse right / left (A) 6.3 A / 0.400
Transport weight (kg) approx. 47
Wall-mounting plate space requirement (mm) (H x W x D) 1030 x 900 x 250
Installation space required (mm) approx. 500 x 1300
Product capacity (l) 40 l
Water softening system Reverse osmosis (integrated on mounting plate)
Power section integrated on mounting plate
   
Operating conditions  
Connected load 0.3 kVA
Service water Water quality in accordance with the European Drinking Water Ordinance
Water hardness max. 20°dH
Drinking water connection 1/2“
Min./Max. room temperature (°C) 10 – 32
Service water inlet temperature (°C) 10 – 27
Operating water inlet pressure (bar) 2,5 – 3
System pressure after pressure reducer approx. 2 bar
Ventilation of the installation room Air exchange rate min. 2m³/h per m³ room volume (recommended)
Hydrogen discharge min. d25 continuously increasing, leading outwards
Storage temperatures (°C) 5 – 40
Max. humidity (%) 90%, non-condensing
separate operating room No
Interfaces Wireless LAN / dinoAccess
dinotecNET+ / P20 (Option)
Modbus RTU (Option)
Recommended operating materials Salt quality dinosolit (approved in accordance with the Biocidal Products Directive)
Channel min. DN40
   
All information subject to errors and technical changes.