Short description
dinotec electrolysis systems for production of a highly effective disinfection solution from common salt, stable when stored. The basic version of the controller already includes redox and pH measurement as well as the corresponding dosing outputs.
Description
dinotec electrolysis systems for production of a highly effective disinfection solution from common salt, stable when stored. Integrated product tank to cover peak demand. The basic version of the controller already includes redox and pH measurement as well as the corresponding dosing outputs. The measurement technology can be easily extended to a complete measurement and control system for chlorine, redox and pH. Special characteristics Main system components are:
Technical data
System housing:
Plastic housing, protection class: IP 65
Supply voltage:
230V / 50Hz
Energy demand:
approx. 0.36kW/h
Display:
via large graphical display 100 x 30 mm
Operation:
Clear text menu with keys
Language:
Language selection
Production output:
approx. 60 g chlorine/h
Product concentration of:
approx. 6.4 g chlorine/l
Salt consumption:
approx. 236 g NaCl/h
Space requirements wall mounting plate:
1212 x 772 x 195 mm (hxwxd)
Transport weight:
approx. 55 kg
Operating weight:
approx. 59 kg
Flow control and monitoring
Yes
Monitoring of back pressure in hydrogen line
Yes
Softening plant:
integrated
Refill control in softener
Yes
Type of Operation:
stand-alone
Redox measuring amplifier
Measuring range:
-1500 mV to +1500 mV
Resolution:
1 mV
Ambient temperature influence:
50 ppm/K (12 mV)
Reference temperature:
23° C
Input resistance:
> 1012 ohm
Redox measurement:
via combination electrode without reference system
Calibration:
not required
pH measuring amplifier
Measuring range:
-1500 mV to +1500 mV
Resolution:
0.01 pH or 1 mV
Ambient temperature influence:
50 ppm/K (12 mV)
Reference temperature:
23° C
Input resistance:
1012 ohm
Calibration pH:
optional single-point or two-point calibration
Electrode check:
automatically after calibration
Temperature compensation of pH value:
automatic via PT1000 or manually adjustable
Temperature
Temperature input for measuring sensor:
PT1000
Measuring range:
-30°C to +140°C (+/-1%)
Inputs/outputs, control response
Type of control:
P, PI, or PID control optionally
Control:
optionally 1-position
Binary outputs:
2 potential-free output relays for disinfection, pH reduce/pH raise (pulse length, pulse frequency, On/Off), alarm
Maximum contact load (230V/AC):
370 W (inductive), 500 W (Ohm resistive load)
Max. switching current:
30V/10A, 115V/0,3A, 230V/0,12A
Digital inputs:
Empty signal chlorine, pH reduce, dosing stop
Environmental conditions
Working temperature:
5 to +50 C°
Storage temperature:
20 to 65 C°
Rel. humidity:
max. 90 % at 40 °C (non-condensing)
Application
Ecological and safety-conscious production of a disinfection solution containing chlorine for use in drinking water and process water disinfection, swimming pool water treatment to maintain the quality of hygiene parameters (TVO - German drinking water regulations, § 11 UBA - German Federal Environment Office). It must be ensured that only high-quality salt according to the manufacturer's specifications is provided as operating material for the Vodes BlueWave systems. Non-observance results in an exclusion of any statutory warranty/warranty claims. Manufacturer specifications for salt: NaCl min. 99.90 % / hardeners (sum Ca and Mg) max. 50 ppm / sulphate (SO4) < 400 ppm / bromide (Br) < 75 ppm / manganese (Mn) < 1 ppm / iron (Fe) < 2 ppm / components insoluble in water < 0.1 %. We recommend the use of dinosolit special salt tablets, otherwise it's the operator's responsibility to monitor the salt quality.
Safety information
No handling of or contact with hazardous materials required.
Disposal informations
There are no waste products that require a special form of disposal.
Storage instructions
Work environment for electronics
Storage temperature:
20 to 65 C°
Rel. humidity:
max. 90 % at 40 °C (non-condensing)
Supplementary information
Preliminary works by customer Installation of a backflow preventer, air inlet valve or pipe separator required, if demanded by the local utility companies. A separate technical room is not required.
Accessories
dinodos EASY, capacity 0.2 - 4.5 l/h
Peristaltic dosing pump in wall mounting case
Hose connection 6/4 mm
dinodos START
Peristaltic dosing pump in wall mounting case
with power cord l = 1.8 m grey, hose connector 6/4 mm
Dosing line, DN 4, 6/4 mm, PE, yellow
standard, for pH and flocculation, cut to 6m each
rolled and fixed with bands
Dosing line, DN4, 6/4mm, 6m piece
PTFE for extreme loads (10 bar up to 100°C)
rolled and fixed with bands
Extension set Cl, pH, Rx for VoDes BlueWave
with dinodos START, measuring board, measuring cell universal FM,
electrodes and accessories mounted on a plate
Extension set Rx, pH for VoDes BlueWave
with dosing technology dinodos EASY, flow cell,
electrodes and accessories mounted on a plate
Measurement technology CL, pH, Rx with measuring board
Measuring cell universal fm up to 10 bar, electrodes
and accessories mounted on a plate - for process water
Measurement technology CL, pH with measuring board
Measuring cell universal fm up to 10 bar, electrodes
and accessories mounted on a plate - for process water