Short description
The dinotec membrane cell electrolysis process with Marathon technology provides a stock of concentrated, highly active sodium hypochlorite solution on site on the basis of a saline solution. With the integrated dinotecNET+ control with Marathon technology, the most important operating parameters are recorded and controlled, meaning the system is always operated at the optimum operating point with continual self-optimization. The Marathon technology ensures that the proven system achieves an extremely high level of efficiency, combined with a low material stress. The result in an up to 15% lower energy consumption, and an extremely economic service life of the electrolysis cells. Transparent safety, intelligent control and easy accessibility of the technology are additional obvious advantages of the system.
Description
Including all system components in a free standing and self-supporting frame bearing structure made of high-quality stainless steel. Use of chemically resistant and process-compatible materials such as titanium, PVDF, PVC-C and PVC-U. Due to the specially developed control and optimization system, the clear text display for all operating conditions and control states allows the query and remote control of all important parameters! In addition, the system features a BUS interface and a special protocol routine for further electronic archiving (e.g. event logs).
Technical data
System-specific connections:
Connected power:
15 kVA, 3 x 400V/50Hz
Fresh water consumption:
approx. 195 l/h,
Fresh water supply pressure:
mind. 3 bar, max. 8 bar
Fresh water temperature:
8°C to 15°C
Process technology
Production output:
approx. 2.0 kg active chlorine/h, max 48 kg/day (depending on local operating conditions)
Product concentration:
approx. 3% - corresponds to water hazard class 1
Energy demand:
approx. 3.6 kg/1 kg chlorine
Salt demand:
approx. 2.3 kg/1 kg chlorine
Hydrogen pipe:
min. d110 x 5.3 – continuously rising
Mounting frame:
high-alloy stainless steel 1.4301 with additional special passivation of profile surface, free-standing and self-supporting
Length of pipe to product tank:
< 5 m
Dimensions (wxhxd):
900 x 2150 x 1580 mm
Mass/weight:
approx. 245 kg
Power module
Dimensions (wxhxd):
600 x 1300 x 400 mm
Mass/weight:
Approx. 160 kg
Can be set up separately from electrolyser unit.
Specifications for the installation room
Supply air port for installation room:
min. 800 cm2
Permissible room temperature:
+10 to +30 °C
Ceiling height:
min. 2.6 m
Application
Ecological and safety-conscious production of a low chloride, highly concentrated and long-term stabilized disinfection solution for use in professional pool water treatment as well as drinking water disinfection to maintain and safeguard the quality of the hygiene parameters (TVO - German drinking water regulations, § 11 UBA - German Federal Environment Office). The freshly produced electrolysis product is taken from the product storage tank as required, and added to the water to be treated by means of a separate measuring, control and dosing station that is independent of the electrolysis system.
Safety information
No handling of or contact with hazardous materials required.
Minimum energy input. Installation in residential areas possible without the need for prior coordination of possible damage with public authorities (police, fire brigade etc.). Clear text display and clearly visible operating states. Controlled hydrogen discharge to the outside.
Disposal informations
There are no waste products that require a special form of disposal.
Storage instructions
The regulations of § 19 WHG (German Federal Water Act) apply. There are no further requirements for storage of products < 1000 l. Chlorine produced by electrolysis is classified as "WGK 1", low hazardous to waters according to water pollution classes. When storing quantities of > 1000 l of the product, only a separate drip pan with integrated leakage probe is required. (As per 2015)