Description
Microprocessor-controlled measuring and control device, optionally for redox / pH or Poolcare (time-controlled) / pH, in splash-proof plastic housing, wired ready for connection 230V/50Hz. Display of measuring values on backlit graphical display with alphanumeric characters. Menu navigation via clear text display with selection of the desired language. Operating status, warning and alarm messages in clear text via the status bar on the display. Compact measuring and control device for the measuring options: Free switching between measurement options. By adding the "potentiostatic measuring board for the Poolcontrol DYNAMICS", it is possible to implement additional measuring options.
Characteristics of system unit in wall-mounted case for disinfection and dosing equipment:
Compact measuring cell universal fm 4/2 for 2 probes incl. flow measurement/restriction for sample water return or free drain.
Pressure-resistant compact measuring cell for a potentiostatic probe (such as Cl2, ClO2, O3 or Poolcare), a pH or a redox probe and a PT1000 temperature sensor.
Integrated turbine for recording the sample water flow and for a flow compensation of the potentiostatic measurement. The maximum flow is limited by means of a flow restrictor. The counter electrode required for potentiostatic measurement is pre-assembled in the compact measuring cell. A sampling valve is integrated in the measuring cup which can be easily unscrewed. The compact measurement cell can be operated under pressure or depressurized.
The fiber filter is used to retain impurities in the sample water to prevent entry in the measuring cell. Fiber filter with transparent filter cup and cleanable strainer, small mesh size, standardized connections for installation in front of a measuring cell.
Measuring accessories for measurement of the parameters chlorine and pH.
This includes:
Microprocessor-controlled peristaltic dosing pump for an automatic addition of any kind of liquid media, even smallest quantities. With stepper motor and continuously variable digital speed control. Activation by the touch of a button or control via switching contact (ON/OFF), current and frequency control. It can be easily ventilated by the touch of a button and can dose at 100 percent capacity for a minute by pressing a button.
The delivery rate is infinitely variable via the control or two potentiometers on the pump.
With integrated dosing pump hose and hose connector.
Canister low level signal input and fault output are included, a hose rupture is detected automatically. The pump is safe for continuous operation and features a thermal protection.
Operating conditions are signalled via LEDs.
Technical data
System housing:
Plastic housing, protection class: IP 65
Dimensions system housing:
260 x 260 x 85 mm (w x h x d)
Weight:
approx. 1.5 kg
Mains voltage:
115 / 230V/AC, 48-63Hz
Power consumption:
10 VA (w/o dosing equipment)
Display:
via large graphical display 100 x 30 mm
Operation:
Clear text menu with keys
Language:
Language selection
Working temperature:
5 to +40 °C
Storage temperature:
-20 to +65 C
Rel. humidity:
max. 90 % at 40 °C (non-condensing)
Safety management:
Interfaces
RS 485:
for connection to dinowin / Profibus Gateway / etc.
dinotecNET+:
for connection to dinotecNET+ as field device
Redox measuring amplifier
Measuring range:
-1500 mV to +1500 mV
Resolution:
1 mV
Ambient temperature influence:
50 ppm/K (12 mV)
Reference temperature:
23° C
Input resistance:
> 1012 ohm
Redox measurement:
via combination electrode without reference system
Calibration:
not required
pH measuring amplifier
Measuring range:
-1500 mV to +1500 mV
Resolution:
0.01 pH or 1 mV
Ambient temperature influence:
50 ppm/K (12 mV)
Reference temperature:
23° C
Input resistance:
1012 ohm
Calibration pH:
optional single-point or two-point calibration
Electrode check:
automatically after calibration
Temperature compensation of pH value:
automatic via PT1000 or manually adjustable
Temperature
Temperature input for measuring sensor:
PT1000
Measuring range:
0 to +60 °C (+/-1%)
Inputs/outputs, control response
Type of control:
P, PI, or PID control optionally
Control:
optionally 1-position or 2-position controller
Binary outputs:
4 potential-free output relays for chlorine, pH reduce and pH raise (pulse length, pulse frequency, On/Off), alarm
Alternative to pH raise:
Flocculant dosing On/Off
Maximum contact load (230V/AC):
370 W (inductive), 500 W (Ohm resistive load)
Max. switching current:
30V/10A, 115V/0,3A, 230V/0,12A
Digital inputs:
Empty signal chlorine, pH reduce, dosing stop
Analog output:
0(4) - 20mA for individual measuring values (optional)
Cable cross section of connection terminal
0.25 - 2.5mm²
universal FM 4/2
Threaded connection for measuring probes:
2 x PG 13.5
Threaded connection for temperature sensor PT 1000 with straight fitting:
M 12 x 1
Max. pressure:
1.5 bar at 20 °C
Max. sample water temperature:
70°C
Sample water flow:
40 l/h - 120 l/h
Flow restriction:
120 l/h
Sample water monitoring:
< 40 l/h
Flow measurement:
Sample water turbine with Hall-effect generator
Min. differential pressure:
0.3 bar
Connection supply and drain:
sample water hose 6/8mm
Material measuring cell:
PP
Material counter electrode:
stainless steel V4A
Dimensions (mm):
150 x 240 x 110 (wxhxd)
Fibre filter
Holder made of
PP black
Filter cup made of
PA transparent
Inlet/outlet
¼“ inside
Operating pressure
max. 8 bar
Operating temperature
min. 0°C to max. 50°C
Mesh size
0.25mm
Dimensions:
58 x 58 x135mm (wxdxh)
Weight
Approx. 0.15 kg
Measuring accessories
Operating temperature:
0 to +45°C
Storage temperature:
+20 to +65°C
Rel. humidity:
max. 90% at 40°C, non-condensing
dinodos START Choose between:
Mains voltage:
230V +/-10 %, 50/60Hz
Power consumption:
approx. 16 VA max.
Protection class:
IP 65
Dimensions housing (w x h x d):
approx. 170 x 90 x 130 mm
Weight:
approx. 1.5 kg
Permissible ambient temperature:
+10 to +45 oC
Drive:
Stepper motor
Pump hose:
compl. with connection pieces for suction line D4
Capacity max.:
approx. 0.045-9.0 l/h (infinitely variable), at a counterpressure of max. 1.5 bar
Speed range:
0.01 rpm up to 100 rpm
Frequency range pulses:
0.02 pulse/sec. - 1 pulse/sec.
Suction lift max.:
1.80 m
Operation:
Capacity infinitely adjustable via two potentiometers
Control methods:
Empty signal connection:
Normally closed contact / normally open contact (switchable)
Hose leak detection:
Integrated contacts in pump housing
Application
For water treatment in swimming pools, hot tubs and the like.
Spare parts
Fiber filter 3/4", connection 8/6 mm
with screen tube 0.5mm,
hose connection 8/6 mm on both sides
Calibration solution pH 4.0, 50 ml
Calibration solution pH 7.0, 50 ml
Redox electrode without reference system
for dsc compact systems
and Poolcontrol 1000/S/avant
Measuring cable with integrated reference cable
for pot. measurements (chlorine, ozone, Poolcare),
with plug, length 1.2 m
Suction line, flexible, with lid screw MÜ 61
Without float switch, ball check valve and plug
Hose 6/4mm, DN 4 1.5m, for dinodos Easy, START, Concept pumps