Description
Microprocessor-controlled measuring and control device, optionally for redox / pH or Poolcare (time-controlled) / pH, in splash-proof plastic housing, wired ready for connection 230V/50Hz. Display of measuring values on backlit graphical display with alphanumeric characters. Menu navigation via clear text display with selection of the desired language. Operating status, warning and alarm messages in clear text via the status bar on the display. Compact measuring and control device for the measuring options: Free switching between measurement options. By adding the "potentiostatic measuring board for the Poolcontrol DYNAMICS", it is possible to implement additional measuring options.
Characteristics of system unit in wall-mounted case for disinfection and dosing equipment:
Compact measuring cell universal fm 5/3 for 3 probes incl. flow measurement/restriction for sample water return or free drain. Pressure-resistant compact measuring cell made of PP for a potentiostatic probe (such as Cl2, ClO2, O3 or Poolcare), a pH and a redox probe. Note: Can be used for water with a chloride concentration of less than 500mg/l
Integrated turbine for recording the sample water flow and for a flow compensation of the potentiostatic measurement. The maximum flow is limited by means of a flow restrictor.
The counter electrode required for potentiostatic measurement is pre-assembled in the compact measuring cell. A sampling valve is integrated in the measuring cup which can be easily unscrewed. The compact measurement cell can be operated under pressure or depressurized.
The fiber filter is used to retain impurities in the sample water to prevent entry in the measuring cell. Fiber filter with transparent filter cup and cleanable strainer, small mesh size, standardized connections for installation in front of a measuring cell.
Measuring accessories for measurement of the parameters chlorine, redox and pH.
This includes:
Technical data
System enclosure:
Plastic housing, degree of protection: IP 65
System enclosure dimensions:
260 x 260 x 85 mm (W x H x D)
Weight:
approx. 1.5 kg
Mains voltage:
115 / 230 V/AC, 48-63 Hz
Power consumption:
10 VA (without metering technology)
Display:
via large-area graphical display 100 x 30mm
Operation:
Plain text menu with buttons
Language:
Language selection
Operating temperature:
5 to +40 °C
Storage temperature:
-20 to +65 °C
Rel. humidity:
max. 90% at 40 C°, non-condensing
Safety monitoring:
Interfaces:
RS 485:
for connection to dinowin / Profibus gateway / etc.
dinotecNET+:
for connection to dinotecNET+ as a field device
Redox measuring amplifier:
Measuring range:
-1500mV to +1500mV
Resolution:
1 mV
Ambient temperature influence:
50ppm/K (12mV)
Reference temperature:
23 °C
Input resistance:
> 1012 Ohm
Redox measurement:
via dip-type measuring chain without drainage system
Calibration:
not required
pH measuring value amplifier:
Measuring range:
-1500mV to +1500mV
Resolution:
0.01 pH or 1 mV
Ambient temperature influence:
50ppm/K (12mV)
Reference temperature:
23 °C
Input resistance:
1012 Ohm
Calibration pH:
Optional one-point or two-point calibration
Electrode test:
automatically after calibration
Temperature compensation of the pH value:
can be set automatically or manually via PT1000
Temperature:
Temperature input for sensor:
PT1000
Measurement range:
0 to +60 °C (+/-1%)
Inputs/outputs, control behaviour:
Control response:
Selectable P, PI or PID control
Control:
Optional 1-point or 2-point control
Binary outputs:
4 volt-free output relays for chlorine, lower pH and raise pH (pulse length, pulse frequency, on/off), alarm
Alternatively to raising pH:
Flocculation dosing On/Off
Maximum contact load (230V AC):
370W (inductive), 500W (resistive load)
Maximum switching current:
30V/10A, 115V/0.3A, 230V/0.12A
Digital inputs:
Empty alarm chlorine, pH lowering, dosing stop
Analogue output:
0(4)-20mA for single measured value (optional)
Conductor cross-section terminal block:
0.25 - 2.5mm²
universal FM 5/3
Threaded connection for measuring probes:
3 x PG 13.5
Threaded connection for temperature sensor PT 1000 with straight fitting:
M 12 x 1
Max. pressure:
10 bar at 20 °C
Max. sample water temperature:
70°C
Sample water flow:
40 l/h - 120 l/h
Flow restriction:
120 l/h
Sample water monitoring:
< 40 l/h
Flow measurement:
Sample water turbine with Hall-effect generator
Min. differential pressure:
0.3 bar
Connection supply and drain:
8 mm plug-in system
Material:
PP
Dimensions (mm):
150 x 240 x 110 (wxhxd)
Fibre filter
Holder made of
PP black
Filter cup made of
PA transparent
Inlet/outlet
¼“ inside
Operating pressure
max. 8 bar
Operating temperature
min. 0°C to max. 50°C
Mesh size
0.25mm
Dimensions:
58 x 58 x135mm (wxdxh)
Weight
Approx. 0.15 kg
Measuring accessories
Operating temperature:
0 to +45°C
Storage temperature:
+20 to +65°C
Rel. humidity:
max. 90% at 40°C, non-condensing
Application
For water treatment in swimming pools, hot tubs and the like.
Spare parts
Fibre filter 3/4", connection 8/6mm
with slotted tube 0.5 mm
double-sided hose connection 8/6mm
pH 4.0 buffer solution 50 ml
pH 7.0 buffer solution 50ml
Rx electrode without lead-out system
for dsc compact systems
and Poolcontrol 1000/S/avant
Measuring cable, with integr. reference cable
for potentiometric measurements (chlorine, ozone, pool care),
with plug, length 1.2 m
Special liquid cleaner for all measuring electrodes














Deutsch (DE)
English (UK)