• Product information

    Pool and Spa Management

  • Net+ module for the hydrostatic level measurement of liquids in unpressurised containers.

  • CLM2 - Container Level Module
  • Art. no.: 2520-090-00



Short description

Container Level Module CLM2 for hydrostatic level measurement of liquids in unpressurised containers. (e.g. canisters with water treatment agent). The module has two separate measuring inputs, as well as inputs for two optional limit contacts. (e.g. leak detection). All connections are plug-in, allowing the module to be quickly mounted and replaced.

 

Description

Container Level Module CLM2 for hydrostatic level measurement of liquids in unpressurised tanks. The module features two separate measuring inputs, as well as inputs for two optional limit contacts. Three diagnostic LEDs indicate the correct operating voltage as well as the reception and transmission of bus data. The module is suitable for mounting on 35 mm DIN rails and is supplied with a 4-pin plug-in terminal. The software integration of the module is carried out via the dinotec NET+ system.

 

Technical data

Function Electrical characteristics
dinotec NET+ system bus RJ12 socket (6-6)
Power supply (bus) 20V- 30V DC (nominal 24V)
Maximum power consumption 3.0W
Standard device address CLM2 10 (on delivery)
Status display
  • Bus voltage OK links
  • Centre module transmits
  • Right bus is active
Pressure P0 Pressure measurement input
Pressure P1 Pressure measurement input
Digital input 0 Input for volt-free switching contact
Digital input 1 Input for volt-free switching contact
   
Input Function
Channel 0 Bit address 0
LED Input for volt-free switching contact
On ON status contact < 100R
Off Status OFF

connections AIM4  
 1 - Air hose Di = 2.4 mm
 
 2 - Float switch connection cable
 
 3 - Level in the tank
 
 4 - Float switch for leak detection
 
 
 
 
 
 
 
 
 
 

Mechanical characteristics NET+ modules  
Conductor cross-section connection terminals 0.25 - 2.5 mm²
Tightening torque of the clamping screws 0.5 Nm max.
Enclosure for DIN rail mounting 
(Standard EN50022 profile 35mm x 7,5mm)
Plastic 40x155x70 mm³ W/D/H
Ambient temperature 0 to 50° C
Protection rating IP 20
Weight 0.250 kg

Mechanical characteristics CLM2  
Hose connection (DI) 2/4mm
Maximum hose length 10m

 

Application

Detection of level states (level 0 - 120cm) in unpressurised open containers. 
Monitoring of level switches.

 

 

 

 

 

 

Supplementary information

This module is a component of the dinotecNET+ pool and spa management system. Ask your specialist dealer about additional modules and field devices for a wide range of applications.

 

Accessories

0220-282-00

dinodos START

Peristaltic dosing pump in wall-mounted housing

with mains cable L = 1.8 m grey, hose connection 6/4 mm

 

  •